<ErrorNumber>7007</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: position register not accurate
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This error should not be reported during normal operation.  An attempt has been made to
move the carriage to a position, but the position register is not accurate. The carriage
position register is initialized automatically when necessary by sending the carriage to the
home switch at the beginning of a command.  It may be possible to cause this error using
monitor commands.
</text></DescriptionText>
<DescriptionText><text>
If this error occurs during normal operation (i.e. no monitor commands used) a firmware
bug should be reported.  If this error occurs while using a monitor command, the
"carriage init" command should be used before attempting the command again.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo service
</text></DescriptionText>
</OperatorAction>
<Cause>
Carriage commands issued through the diagnostic monitor
</Cause>
<Cause>
Currently unknown firmware or hardware bug
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:28 2008 PST
</Updated>
<Links>
</Links>
</Error>